Acoustic Tests
 
 Note: The Δ IIC is a new ASTM test that measures the improvement in decibels. Example a Δ IIC 25 would mean a 25 point  improvement .  The Δ IIC tests is only tested on a 6" concrete slab with no ceiling below.

Product/ Model

Floor / Ceiling Assembly Description

Floor Covering

IIC Rating

Test #

No Underlayment 6" concrete slab-no ceiling None IIC 27 JP-1A  Before
Jumpax 6" concrete  slab - no ceiling Linoleum Sheet IIC 51 JP-1B   After
No Underlayment 6" concrete slab no ceiling Vinyl Composition Tile IIC 31 JP-2A  Before
Jumpax 6" concrete slab no ceiling  Vinyl Composition Tile IIC 51 JP-2B   After
Jumpax 6" concrete slab no ceiling  Vinyl Composition Tile Δ IIC 25 JP-3A
Jumpax

Wood frame construction 2 x 16" - 24" centers, 5/8" T&G plywood w/ 1 1/2" lightweight concrete topping-  batt insulation, RC-1 channel, 5/8" GWB

Linoleum Sheet IIC 54 JP-4A
Jumpax Wood frame construction 2 x 10" - 16" centers, 5/8" T&G plywood w/ 1 1/2" lightweight concrete topping-  batt insulation, RC-1 channel, 5/8" GWB Vinyl Sheet FIIC 55 JP-5A
Jumpax Wood frame construction TGI Joists 16" centers, 5/8" T&G plywood w/ 1" lightweight concrete topping-  batt insulation, RC-1 channel, 5/8" GWB Vinyl Sheet FIIC 57 JP-6A
No Underlayment 8" concrete slab no ceiling None FIIC 34 JP-7A
No Underlayment 8" concrete slab no ceiling Vinyl Strip FIIC 44 JP-7B
Jumpax 8" concrete slab no ceiling Vinyl Strip FIIC 61 JP-7C

Note: The FIIC is a IIC test is performed in the field and is shown as a FIIC rating, it is the same tested and tested in the same manner except it is performed in the field.